GAS GENERATOR MODEL
10.5 kVA / 15 kVA / 20 kVA / 25 kVA / 100 kVA / 125 kVA
DESCRIPTION
Silence is Golden: India’s most silent Genset brand
Mahindra Powerol’s ‘Spectro’ series of diesel gensets is one of the most silent gensets manufactured by the brand. It has sturdy wheels and a long handle which allows easy mobility of the genset.
SEGMENTS USED FOR
- BUNGALOWS
- SMALL OFFICES
- SMALL SHOPS
DIESEL GENERATOR FEATURES
Its recovery time, easily the best in its category, guarantees a seamless switchover to the back-up power. Moreover, its effective governing system controls the voltage fluctuations, thus ensuing complete safety of your equipments.
Its got one of the most preferred engines fitted inside – the Mahindra Powerol engine. Compact and low on vibration, this engine has the smallest footprint as compared to other engines of identical ratings. Making the DG set apt even for roof-mountings.
Each and every Powerol DG set complies with the most stringent noise and emission norms stipulated by the Central Pollution Control Board of India (CPCB).
It’s got other advantages too. Like, it’s transported through the Mahindra Transport Solutions Group. It is installed and commissioned through a Mahindra authorized dealer. It even comes with an annual maintenance contract. It is most fuel efficient in its class It offers zero-leak engines Manual and AMF control panel options are also available
A Powerol DG set can be used in the Telecom, Defence and Railway sectors. It can also be installed at places like petrol pumps, hospitals, super markets, banks and construction sites
TECHNICAL SPECIFICATION
10.5 kVA
15 kVA
20 kVA
25 kVA
100 kVA
125 kVA
10.5 kVA
PARAMETERS | DG MODELS | ||||||
---|---|---|---|---|---|---|---|
Genset Prime Rating (kVA) * | 10.5 | ||||||
Duty (Standby/ Prime) | Prime | ||||||
Power Rating @ 100% kWe (in KW) | 8.4 | ||||||
No. of Phases | 1 Ph / 3 Ph | ||||||
Output Voltage (V) | 230 / 415 | ||||||
Power Factor (lagging) | 0.8 | ||||||
Current (A) | 45.6/14.6 | ||||||
Frequency (Hz) & RPM | 50/1500 | ||||||
Governing Class | G2 | ||||||
Genset dimensions (L x W x H) in mm | 1875 X 1000 X 1195 | ||||||
Genset Weight (Kg) Approx. | 720 | ||||||
Engine Specification | |||||||
Make | Mahindra | ||||||
Model | mGreen3235NGC4+ | ||||||
Power Output# (Kw) | 16.7/23 | ||||||
Aspiration | NA | ||||||
No. of cylinders | 3 | ||||||
Bore x Stroke (mm) | 88.9 X 110 | ||||||
Displacement (Ltr) | 2.05 | ||||||
Cooling System | Liquid Cooled | ||||||
Fuel consumption @ 75% load (kg/hr) ** | 2.0 | ||||||
Fuel consumption @ 100% load (kg/hr)** | 2.3 | ||||||
Starting system | 12 V DC Electrical | ||||||
Air Cleaner | Dry Type | ||||||
Lube oil specification | Maximile CNG Plus | ||||||
Total lubrication system capacity | 6.5 | ||||||
Lube oil consumption @ full load$ | 0.15% of Fuel consumption | ||||||
Lube oil change period (hrs.) | 500 | ||||||
Radiator coolant capacity (liter) | 5.5 | ||||||
Alternator | |||||||
Make | CG/LS/STAMFORD | ||||||
Enclosure Type | IP 23 | ||||||
Voltage regulation | +/- 1% with 4% engine Governing | ||||||
Class of insulation | H | ||||||
Maximum Unbalanced Load across Phases | 25% |
- * A tolrance of +/- 5% will applicable on declared power values
- ** Genset Height is without silencer
- ***A tolrence of +5% shall be applicable on fuel consumption values on account of product to product variation due to engine & +3% of tolarence due to alternator product to product variations
15 kVA
PARAMETERS | DG MODELS | ||||||
---|---|---|---|---|---|---|---|
Genset Prime Rating (kVA) * | 15 | ||||||
Duty (Standby/ Prime) | Prime | ||||||
Power Rating @ 100% kWe (in KW) | 12 | ||||||
No. of Phases | 1 Ph / 3 Ph | ||||||
Output Voltage (V) | 230 / 415 | ||||||
Power Factor (lagging) | 0.8 | ||||||
Current (A) | 65.2/20.9 | ||||||
Frequency (Hz) & RPM | 50/1500 | ||||||
Governing Class | G2 | ||||||
Genset dimensions (L x W x H) in mm | 1875 X 1000 X 1195 | ||||||
Genset Weight (Kg) Approx. | 765 | ||||||
Engine Specification | |||||||
Make | Mahindra | ||||||
Model | mGreen3235NGC4+ | ||||||
Power Output# (Kw) | 16.7/23 | ||||||
Aspiration | NA | ||||||
No. of cylinders | 3 | ||||||
Bore x Stroke (mm) | 88.9 X 110 | ||||||
Displacement (Ltr) | 2.05 | ||||||
Cooling System | Liquid Cooled | ||||||
Fuel consumption @ 75% load (kg/hr) ** | 2.4 | ||||||
Fuel consumption @ 100% load (kg/hr)** | 3.1 | ||||||
Starting system | 12 V DC Electrical | ||||||
Air Cleaner | Dry Type | ||||||
Lube oil specification | Maximile CNG Plus | ||||||
Total lubrication system capacity | 6.5 | ||||||
Lube oil consumption @ full load$ | 0.15% of Fuel consumption | ||||||
Lube oil change period (hrs.) | 500 | ||||||
Radiator coolant capacity (liter) | 5.5 | ||||||
Alternator | |||||||
Make | CG/LS/STAMFORD | ||||||
Enclosure Type | IP 23 | ||||||
Voltage regulation | +/- 1% with 4% engine Governing | ||||||
Class of insulation | H | ||||||
Maximum Unbalanced Load across Phases | 25% |
- * A tolrance of +/- 5% will applicable on declared power values
- ** Genset Height is without silencer
- ***A tolrence of +5% shall be applicable on fuel consumption values on account of product to product variation due to engine & +3% of tolarence due to alternator product to product variations
20 kVA
PARAMETERS | DG MODELS | ||||||
---|---|---|---|---|---|---|---|
Genset Prime Rating (kVA) * | 20 | ||||||
Duty (Standby/ Prime) | Prime | ||||||
Power Rating @ 100% kWe (in KW) | 16 | ||||||
No. of Phases | 1 Ph / 3 Ph | ||||||
Output Voltage (V) | 230 / 415 | ||||||
Power Factor (lagging) | 0.8 | ||||||
Current (A) | 87 / 27.8 | ||||||
Frequency (Hz) & RPM | 50/1500 | ||||||
Governing Class | G2 as per ISO 8528 part 5 | ||||||
Genset dimensions (L x W x H) in mm | 2285 X 1030 X 1255 | ||||||
Genset Weight (Kg) Approx. | 857 | ||||||
Engine Specification | |||||||
Make | Mahindra | ||||||
Power Output# (Kw) | 26.8 | ||||||
Aspiration | NA | ||||||
No. of cylinders | 4 | ||||||
Bore x Stroke (mm) | 88.9 x 101.6 | ||||||
Displacement (Lit) | 2523 | ||||||
Fuel consumption @ 75% load (kg/hr) ** | 3.6 | ||||||
Fuel consumption @ 100% load (kg/hr)** | 4.4 | ||||||
Starting system | 12 V DC Electrical | ||||||
Lube oil specification | Maximile CNG Plus | ||||||
Total lubrication system capacity | 7 | ||||||
Lube oil consumption @ full load$ | 0.15% of FC | ||||||
Lube oil change period (hrs.) | 500 | ||||||
Radiator coolant capacity (liter) | 10 | ||||||
Alternator | |||||||
Make | CG/LS | ||||||
Enclosure Type | IP 23 | ||||||
Voltage regulation | +/- 1% with 4% engine Governing | ||||||
Class of insulation | Class H | ||||||
Maximum Unbalanced Load across Phases | 25% |
- * A tolrance of +/- 5% will applicable on declared power values
- ** Genset Height is without silencer
- ***A tolrence of +5% shall be applicable on fuel consumption values on account of product to product variation due to engine & +3% of tolarence due to alternator product to product variations
25 kVA
PARAMETERS | DG MODELS | ||||||
---|---|---|---|---|---|---|---|
Genset Prime Rating (kVA) * | 25 | ||||||
Duty (Standby/ Prime) | Prime | ||||||
Power Rating @ 100% kWe (in KW) | 20 | ||||||
No. of Phases | 1 Ph / 3 Ph | ||||||
Output Voltage (V) | 230 / 415 | ||||||
Power Factor (lagging) | 0.8 | ||||||
Current (A) | 108.7 / 34.8 | ||||||
Frequency (Hz) & RPM | 50/1500 | ||||||
Governing Class | G2 as per ISO 8528 part 5 | ||||||
Genset dimensions (L x W x H) in mm | 2285 X 1030 X 1255 | ||||||
Genset Weight (Kg) Approx. | 865 | ||||||
Engine Specification | |||||||
Make | Mahindra | ||||||
Power Output# (Kw) | 26.8 | ||||||
Aspiration | NA | ||||||
No. of cylinders | 4 | ||||||
Bore x Stroke (mm) | 88.9 x 101.6 | ||||||
Displacement (Lit) | 2523 | ||||||
Fuel consumption @ 75% load (kg/hr) ** | 4 | ||||||
Fuel consumption @ 100% load (kg/hr)** | 5 | ||||||
Starting system | 12 V DC Electrical | ||||||
Lube oil specification | Maximile CNG Plus | ||||||
Total lubrication system capacity | 7 | ||||||
Lube oil consumption @ full load$ | 0.15% of FC | ||||||
Lube oil change period (hrs.) | 500 | ||||||
Radiator coolant capacity (liter) | 10 | ||||||
Alternator | |||||||
Make | CG/LS | ||||||
Enclosure Type | IP 23 | ||||||
Voltage regulation | +/- 1% with 4% engine Governing | ||||||
Class of insulation | Class H | ||||||
Maximum Unbalanced Load across Phases | 25% |
- * A tolrance of +/- 5% will applicable on declared power values
- ** Genset Height is without silencer
- ***A tolrence of +5% shall be applicable on fuel consumption values on account of product to product variation due to engine & +3% of tolarence due to alternator product to product variations
100 kVA
PARAMETERS | DG MODELS | ||||||
---|---|---|---|---|---|---|---|
Genset Prime Rating (kVA) * | 100 | ||||||
Duty (Standby/ Prime) | Prime | ||||||
Power Rating @ 100% kWe (in KW) | 80 | ||||||
No. of Phases | 3 Phase | ||||||
Output Voltage (V) | 415V | ||||||
Power Factor (lagging) | 0.8 | ||||||
Current (A) | 139 | ||||||
Frequency (Hz) & RPM | 50/1500 | ||||||
Governing Class | G2 as per ISO 8528 part 5 | ||||||
Genset dimensions (L x W x H) in mm | 3750 x 1300 x 1700 | ||||||
Genset Weight (Kg) Approx. | 2210 | ||||||
Engine Specification | |||||||
Make | Mahindra | ||||||
Power Output# (Kw) | 114.7 | ||||||
Aspiration | TCI | ||||||
No. of cylinders | 6 | ||||||
Bore x Stroke (mm) | 105 x 137 | ||||||
Displacement (Lit) | 7118 | ||||||
Fuel consumption @ 75% load (kg/hr) ** | 16 | ||||||
Fuel consumption @ 100% load (kg/hr)** | 20 | ||||||
Starting system | 24 V DC Electrical | ||||||
Lube oil specification | Maximile CNG Plus | ||||||
Total lubrication system capacity | 20.2 Ltr | ||||||
Lube oil consumption @ full load$ | 0.15% of FC | ||||||
Lube oil change period (hrs.) | 500 | ||||||
Radiator coolant capacity (liter) | 24 | ||||||
Alternator | |||||||
Make | CG/LS | ||||||
Enclosure Type | IP 23 | ||||||
Voltage regulation | +/- 1% with 4% engine Governing | ||||||
Class of insulation | Class H | ||||||
Maximum Unbalanced Load across Phases | 25% |
- * A tolrance of +/- 5% will applicable on declared power values
- ** Genset Height is without silencer
- ***A tolrence of +5% shall be applicable on fuel consumption values on account of product to product variation due to engine & +3% of tolarence due to alternator product to product variations
125 kVA
PARAMETERS | DG MODELS | ||||||
---|---|---|---|---|---|---|---|
Genset Prime Rating (kVA) * | 125 | ||||||
Duty (Standby/ Prime) | Prime | ||||||
Power Rating @ 100% kWe (in KW) | 100 | ||||||
No. of Phases | 3 Phase | ||||||
Output Voltage (V) | 415V | ||||||
Power Factor (lagging) | 0.8 | ||||||
Current (A) | 174 | ||||||
Frequency (Hz) & RPM | 50/1500 | ||||||
Governing Class | G2 as per ISO 8528 part 5 | ||||||
Genset dimensions (L x W x H) in mm | 3750 x 1300 x 1700 | ||||||
Genset Weight (Kg) Approx. | 2250 | ||||||
Engine Specification | |||||||
Make | Mahindra | ||||||
Power Output# (Kw) | 114.7 | ||||||
Aspiration | TCI | ||||||
No. of cylinders | 6 | ||||||
Bore x Stroke (mm) | 105 x 137 | ||||||
Displacement (Lit) | 7118 | ||||||
Fuel consumption @ 75% load (kg/hr) ** | 20 | ||||||
Fuel consumption @ 100% load (kg/hr)** | 25 | ||||||
Starting system | 24 V DC Electrical | ||||||
Lube oil specification | Maximile CNG Plus | ||||||
Total lubrication system capacity | 20.2 Ltr | ||||||
Lube oil consumption @ full load$ | 0.15% of FC | ||||||
Lube oil change period (hrs.) | 500 | ||||||
Radiator coolant capacity (liter) | 24 | ||||||
Alternator | |||||||
Make | CG/LS | ||||||
Enclosure Type | IP 23 | ||||||
Voltage regulation | +/- 1% with 4% engine Governing | ||||||
Class of insulation | Class H | ||||||
Maximum Unbalanced Load across Phases | 25% |
- * A tolrance of +/- 5% will applicable on declared power values
- ** Genset Height is without silencer
- ***A tolrence of +5% shall be applicable on fuel consumption values on account of product to product variation due to engine & +3% of tolarence due to alternator product to product variations
Let’s Get in Touch
Power your life with Powerol Generators
QUALITY ASSURANCE